1.
World J Nucl Med ; 22(4): 267-275, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152105

RESUMO

Introduction The quality control (QC) procedures for positron emission tomography (PET) scanners are covered by National Electrical Manufacturers Association and International Electrotechnical Commission. QC must be carried out at regular intervals according to the specifications of the scanner manufacturer. Daily and weekly QC plays a valuable role in monitoring positron emission tomography (PET) scanner performance changes. This study shares operational and performance experience of QC procedures that do not require a radioactive Ge-68 source to perform daily QC and experience with fluorodeoxyglucose F18 ( 18 F-FDG) as a substitute for germanium-68/sodium-22 (Ge-68/Na-22) source for weekly QC. Method This study was performed on an uMI550 digital positron emission tomography-computed tomography (PET-CT) scanner. In this scanner daily QC checks system temperature and humidity, system count rate, data link status, and voltage. QC was performed at the console control, the position of the scanner table was in the home position pulled out from the gantry, and the room was closed during the quick QC. Weekly full QC check items include look-up table drift, energy drift, time-of-flight status, C-map status, temperature and humidity, and voltage. Weekly full QC was performed with a 18 F-FDG source in a rod phantom source. Results Over 200 daily QC tests without a radioactive source Ge-68 phantom and 50 full weekly QC tests using a 18 F-FDG rod phantom were performed with this scanner according to the manufacturer's instructions and a test report was generated. No daily QC errors or warnings were observed during this period. Conclusion The new approach for the daily PET QC does not expose operators to radiation. This translates into commercial and operational merits with consistent performance and results. Implications for Practice Reduction in radiation exposure to operating staff during QC procedure in PET-CT scanner.

2.
Radiat Prot Dosimetry ; 193(1): 16-23, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33683324

RESUMO

PURPOSE: Contribution of radiation doses from medical X-ray examination to collective dose is significant. Unusually, high doses may increase the risk of stochastic effects of radiations. Therefore, radiation dose assessment was performed in 241 digital X-ray examinations in the study and was compared with published dose reference levels (DRLs). METHODS: Entrance surface air kerma (ESAK) was calculated in chest PA, cervical AP/Lat, abdomen AP, lumbar AP/Lat and pelvis AP digital radiographic examinations (119 male and 122 female) following the International Atomic Energy Agency recommended protocol. Initially, 270 digital examinations were selected, reject analysis was performed and final 241 examinations were enrolled in the study for dose calculations. The exposure parameters and X-ray tube output were used for dose calculations. Effective doses were estimated with the help of conversion coefficients from ICRP 103. RESULTS: Median ESAK (mGy) and associated effective doses obtained were cervical spine AP (1.30 mGy, 0.045 mSv), cervical spine Lat (0.25 mGy, 0.005 mSv), chest PA (0.11 mGy, 0.014 mSv), abdomen AP (0.90 mGy, 0.118 mSv), lumbar spine AP (1.52 mGy, 0.177 mSv), lumbar spine Lat (7.76 mGy, 0.209 mSv) and pelvis AP (0.82 mGy, 0.081 mSv). Results were compared with the studies of UK, Oman, India and Canada. CONCLUSION: The calculated ESAK and effective dose values were less than or close to previously published literature except for cervical spine AP and lumbar spine Lat. The results reinforce the need for radiation protection optimization, improving examination techniques and appropriate use of automatic exposure control in digital radiography. ESAK values reported in this study could further contribute to establishing local DRLs, regional DRLs and national DRLs.


Assuntos
Proteção Radiológica , Canadá , Feminino , Humanos , Índia , Masculino , Omã , Doses de Radiação
3.
Radiat Prot Dosimetry ; 190(1): 22-30, 2020 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-32491168

RESUMO

The application of the kerma-area product (PKA) meter is increased rapidly in dosimetry. This study presents measurements of PKA in adherence to the International Atomic Energy Agency protocol for 300 adult patients in digital radiographic procedures. Effective doses (ED) were calculated from PKA measurements and conversion coefficients (E-103/PKA) obtained from the International Commission on radiological protection 103. In skull posteroanterior (PA), skull lateral (LAT), cervical spine anteroposterior (AP), cervical spine LAT, chest PA, abdomen AP, lumbar spine AP, pelvis AP and lumbar spine LAT, the third-quartile PKA values were found to be 0.2, 0.28, 0.33, 0.19, 0.26, 0.95, 0.93, 0.96 and 3.15 Gycm2, and estimated mean EDs were 0.005, 0.008, 0.056, 0.021, 0.037, 0.146, 0.165, 0.097 and 0.258 mSv, respectively. The third-quartile PKA values were suggested as local diagnostic reference levels (LDRLs). Results were compared with the diagnostic reference levels (DRLs) of the UK, the European Commission, previously published LDRLs in Greece and China by Metaxas et al. and Zhang and Chu, respectively. The PKA (third-quartile) value for cervical spine AP was 120% higher than UK 2010 DRLs, lumbar spine LAT was 123% higher than LDRLs given by Metaxas et al. and chest PA was 160% higher than UK 2010 DRLs and 225% higher than Metaxas et al. provided LDRLs. The PKA results were lower than the UK, and two studies in Greece by Metaxas et al. except for chest PA, cervical spine AP and lumbar spine LAT showed the need for further optimization. The LDRLs reported in this study may further contribute to establishing future national DRLs.


Assuntos
Proteção Radiológica , Intensificação de Imagem Radiográfica , Adulto , China , Grécia , Humanos , Doses de Radiação , Radiografia Torácica